← All sessions

Friday In-Focus · 6 Feb 2026

The Anatomy of Connected Medical Devices: A Non-Technical Guide to the Ecosystem

Mark of Marcus Engineering explains connected device architecture, common patterns and the questions non-engineers should ask to expose risk.

What the session covered

Mark, engineering director at Marcus Engineering, led this session on the anatomy of a connected medical device. He defined connected devices broadly to include Bluetooth, Wi-Fi and Ethernet links, connections to electronic health records, hospital networks and remote troubleshooting. A central warning was that teams can create a connected device by accident, and that unused radios or interfaces should be physically removed rather than disabled or kept for uncertain future features. Mark then walked through the main building blocks: sensors and effectors, processing and storage, and transmission. He explained common architectures, including device to phone to cloud, device to gateway to cloud, and direct hospital or internet connection. For each part he gave practical questions that non-engineers can ask their engineering teams. These covered what the device actually does, what data it collects, where processing happens, what personally identifiable information and keys are stored, whether the software bill of materials is current, and how updates will work. The phone section covered apps that view data, send alerts, control the device or rely on cloud processing, plus validation across phone models and what happens when an app is killed. The gateway and direct internet patterns raised the need for security expertise, post-market security work and independent penetration testing. Mark also advised treating AI as an untrusted user. The takeaway was a structured way for regulatory, quality and business colleagues to challenge connected device designs and spot red flags early.

Figures

Figures Mark cited

5upcoming events mentioned in the announcements
530,000St. Jude Medical/Abbott pacemakers implanted when a security issue was found in their custom RF protocol
11remove-and-replace surgeries caused by the pacemaker security issue
18people hospitalized for side effects and issues related to the pacemaker security issue

Source: Sean

Chapters

Jump to a moment

  1. Announcements, upcoming events, and introduction of Mark
  2. What counts as a connected device and why unused interfaces should be removed
  3. The four building blocks: sensors, processing, storage, and transmission
  4. Storage, SBOMs, and why device updates are hard
  5. Transmission risks, custom protocols, and the St. Jude pacemaker example
  6. Phones as an uncontrolled part of the system and app risk patterns
  7. Remote control, worst-case commands, overrides, and cloud commands
  8. Phone processing, compatibility testing, PII, and gateway patterns

Times run from the start of the recording.

Take these with you

Six checks

Ask whether it is connectedHave engineering confirm whether the device uses Bluetooth, Wi-Fi, Ethernet, USB, a server, or an EHR connection.
Remove unused interfacesIf a wireless or network interface is not used, physically remove it rather than just turning it off.
Map the data and storageAsk what data the device collects, where processing happens, and whether any PII or security keys are stored.
Demand an update storyAsk how software updates work, whether the SBOM is current, and whether updates were designed in from the start.
Treat the phone as uncontrolledAsk which phones are supported, how compatibility is tested, and what happens if the app is killed or the connection drops.
Ask for the worst possible commandHave engineering describe the worst command that could be sent, how overrides work, and whether the cloud can command the device.

Full recording

64:52

Plays from YouTube when you press play. Cookie settings

How to cite this session

Omo, M. (2026, February 6). The Anatomy of Connected Medical Devices: A Non-Technical Guide to the Ecosystem [Webinar]. MedTech Leading Voice, Friday In-Focus. medtechleadingvoice.com/watch/2026-02-06-the-anatomy-of-connected-medical-devices-a-non-technical-guide-to-the-ecosystem

Earlier sessions

13 Nov 2026Architecting a Claims Support System 6 Nov 2026Methodological Quality and Scientific Validity Under the MDR 30 Oct 2026AI Pre-Submission Review Under the MDR

Latest issues

Issue 191Device Cybersecurity Is Now Post-Market Surveillance Issue 190FDA and the Future of Generative AI Medical Devices Issue 189MDR and IVDR Evidence Requirements in Transition